Calcium Scale Basics
Much of our drinking water comes from ground water, originating as
precipitation and falling to earth in the form of rain or snow. This water
seeps into the ground, filling the open spaces beneath the surface. As
the rain or snow passes through the atmosphere it is enriched with carbon
dioxide (CO2) while combining with H2O to form a solvent of Calcium
known as Carbonic Acid (H2CO3). As this moisture seeps into the
ground, the Carbonic Acid extracts calcium from the earths calcium
rich stone, forming Hydrogen Carbonate (Ca(HCO3)2). As this extraction
process ends, the water is saturated with calcium and carbonic
acid, forming a carbonic acid/calcium equilibrium. The amount of calcium
in our water can be high or low, depending on how much calcium
is drawn into the water. What are the effects of Calcium?
The negative effect of calcium is the scale it creates in or on pipe surfaces,
water heaters, plumbing fixtures, heating elements, R/O systems and water
using devices.
The scale leads to higher energy, operating and maintenence
costs for ice machines, coffee machines, reverse osmosis equipment, water
heaters and other water
using equipment. The scale may also breed bacteria.
Alpha Water Systems has your solution!
How does Calcium Scale develop in pipes and on hardware?
Calcium scale is a hard, thick coating of calcium carbonate (CaCO3) that
forms
on heating elements, in pipes, plumbing fixtures, water using appliances
and
R/O systems. As calcium rich water enters the home, the carbonic acid/calcium
equilibrium is interupted within the pipes, plumbing fixtures, water heaters,
appliances
or water using devices. Because the Hydrogen Carbonate (Ca (HCO3)2)
is a weak chemical compound, increases in temperature or water movement
will cause the compound to breakdown, causing parts of the Calcium (Ca2),
Magnesium
(Mg2) and Bicarbonate (HCO3) to attach to the surfaces of heating elements,
the inside of pipes, water heaters, plumbing fixtures and water using devices.
Over
time the scale coating continually thickens and is very difficult and costly
to remove.
What Calcium treatments are available?
Water Softeners
The “classic” water softening unit operates on the basis of
ion exchange; exchanging calcium and magnesium ions
in the water for sodium ions. When a water softener is
used, the result is not only soft water, but also increased
sodium content in the water supply.
Magnetic and Electric Systems
Magnetic and electric systems are a relatively new invention.
However, these systems only have a very limited effectiveness
at best, not a high enough percentage to prevent
scale altogether.
Polyphosphate
The polyphosphate dissolves into the water and coats the
iron, calcium and magnesium in it, making it difficult for
these agents to precipitate.
Scale Prep SP3 Media
The technologically advanced Scale Prep Sp3 Media is an
innovative solution that prevents all of the negative effects
of calcium and magnesium, while allowing the positive
health benefits to remain
|
|
|
How the Scale Prep
system works:
Scale Prep’s SP3 Anti-Scale Media was especially developed and manufactured
to protect against the formation of scale and remove already existing scale
from pipes and heat exchange surfaces.
The Scale Prep’s SP3 catalytic media prevents the formation of scale and
eliminates existing scale by accelerating the transformation of the calcium
and magnesium minerals into harmless “Nano” particles. As the nano particles
flow through plumbing systems, they do not attach to pipes, fixtures, valves,
or heating elements; the result is 99% scale prevention and removal! Scale
Prep’s SP3 is successfully used in a number of applications for both residential
and commercial usage. Virtually maintenance free, chemical free, and salt
free, Scale Prep’s SP3 media water conditioners are a cost effective alternative
where benefits and overall performance surpasses our competitors.
|
|
AQA 1054 $2399.00
UP TO 25 GALLONS PER MINUTE, NO FLOW RESTRICTION
UP TO 100 GPG
FILTERSORB SP MEDIA
CLACK UP-FLOW IN & OUT VALVE
BYPASS
BIG BLUE FILTER
REPLACEMENT FILTERS
$24.95 EACH LAST ABOUT 6-12 MONTHS
10 YEAR WARRANTY ON TANKS,
HOUSING AND VALV Plus shipping
CALL 973-293-7856 TO ORDER |
|
AQA 1248 $2599.00
UP TO 25 GALLONS PER MINUTE, NO FLOW RESTRICTION
UP TO 100 GPG
FILTERSORB SP MEDIA
CLACK UP-FLOW IN & OUT VALVE
BYPASS
BIG BLUE FILTER
REPLACEMENT FILTERS $24.95 EACH LAST ABOUT 6-12 MONTHS
10 YEAR WARRANTY ON TANKS, HOUSING AND VALVES
Plus shipping
CALL 973-293-7856 TO ORDER
|
|
AQA 1054 X 2
$2875.00
UP TO 25 GALLONS PER MINUTE, NO FLOW RESTRICTION
UP TO 100 GPG GREAT FOR CITY AND WELL WATER.
MINERAL TANK
CARBON FILTER TO REMOVE CHLORINE AND ODORS
FILTERSORB SP MEDIA
CLACK UP-FLOW IN & OUT VALVE
BYPASS
BIG BLUE SEDIMENT FILTER
REPLACEMENT SEDIMENT FILTERS
$24.95 EACH LAST ABOUT 6-12 MONTHS
10 YEAR WARRANTY ON
TANKS, HOUSING AND VALVES Plus Shipping
CALL 973-293-7856 TO ORDER
|
Easy Setup
Easy Installation
NO Salt!
NO Power!
NO Drain!
NO Maintenance
100% Scale Removal for Pipes and Hardware
Long Lifetime
Highly Efficient
10 year warranty on tanks, valve and housing
|
Scale Prep SP3 Operating Parameters
|
|
|
TEMPERATURE
|
41 F- 149 F
|
PH RANGE
|
6-9
|
CHLORINE
|
NO MORE THAN 3 PPM
|
|
IRON
|
NO MORE THAN .4 PPM
|
HYDROGEN PEROXIDE
|
NO MORE THAN . 5
|
|
MANGANESE
|
NO MORE THAN 0.05
|
|
OIL
|
MUST BE REMOVED
|
|
HYDROGEN SULFIDE
|
MUST BE REMOVED
|
POLYPHOSPHATES
|
MUST BE REMOVED
|
GRAINS
OF HARDNESS
|
100 GRAINS. ANY APPLICATION OVER 100 GRAINS
CALL FOR SPECIFICATIONS
|
CONNECTION SIZEs
|
Inches
|
1" -1 1/2"
|
The Scale Prep system, environmentally-friendly
scale control:
• Commercial and Residential applications
• Preserves beneficial minerals
• Does not release harmful minerals or chemicals into our water system
• Maintenance free
• No electricity
• No wasted water
• Chemical free
• Eliminates existing scale
• Reduces soap and chemical consumption by 30-40%
• Salt free
• Reduces energy consumption
• Scale Prep System must be the last form
of water treatment equipment installed
with the exception of an RO unit or POU
filter.
• Recommended to use a carbon pre-filter
for municipal applications (carbon prefilters
reduces the negative effects of
high chlorine on the media and lowest
levels of iron .4ppm. ***Note: You must
change out your carbon filter to keep
proper flow rates).
• Recommended that you soak the media
for 60-120 minutes before start up. This
assures that the media is saturated with
water and will not accumulate at the top
of the housing when filled with water.
• Do not apply phosphates or any other
anti-scalents either before or after the
Scale Prep System.
• Scale Prep Systems uses a Spider
Flexible Hub and Lateral to ensure
proper fluidization. (For larger tanks, use
a hub and lateral with a garnet underbed.
|
|
|
|
1995-2023
Alpha Water Systems Inc.
973-293-7856